下载中心

当前位置:首页>技术新闻>下载中心
全部 8653 内部新闻 12 行业动态 17 视觉技术 876 图像编程 622 下载中心 7126

NI MXI-Express BIOS Compatibility 2023 Q1 x64Win10 32bitEng MXI-Express BIOS兼容性工具NIMXIeCmpt23.0

时间:2023-08-28   访问量:1264

NI MXI-Express BIOS Compatibility 2023 Q1 x64Win10 32bitEng MXI-Express BIOS兼容性工具NIMXIeCmpt23.0

MXI-Express BIOS Compatibility
MXI-Express BIOS Compatibility解决了与MXI-Express兼容的硬件相关BIOS限制。
MXI-Express BIOS Compatibility是一款工具软件,可帮助您使用MXI-Express来分析PXI或PXI Express机箱与计算机之间的连接故障。借助该软件,您可以使用兼容的PXI远程控制模块的MXI-Express功能来忽略或解决常见的BIOS限制。

Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html

视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html

NI MXI-Express BIOS Compatibility 2023 Q1
发布日期:2023/2/8
包含的版本:2023 Q1完整版,版本号23.0.0
受支持的操作系统:
Windows 10
语言:English
校验和
文件大小: 138741760 字节 (132.31 MB)
修改日期: 2023-02-09 09:50
MD5: 7b9dc60cae5fa494f63f502bc038d7f8
SHA1: d81c1dcf725735b78c486c1790ecaa7f38f9c46b
SHA256: d941b6915bfe579b5575bf8b31f4fe054573f2e1d1d243c45ab9ad0758a8770d
CRC32: 415df7eb

百度网盘和NI官方下载地址:
请注册登录机器视觉论坛账号,购买附件查看下载地址

NI MXI-Express BIOS Compatibility 2023 Q1 x64Win10 32bitEng MXI-Express BIOS兼容性工具NIMXIeCmpt23.0

http://visionbbs.com/thread-30708-1-1.html?fromuid=9

(出处: 机器视觉论坛)



MXI-Express BIOS Compatibility 2023 Q1 Readme

January 2023

This file contains installation instructions and compatibility information for MXI-Express BIOS Compatibility 2023 Q1.

You can find more release information on ni.com.


Supported Operating Systems

Installation Instructions

Product Security and Critical Updates

New Features

Supported Hardware

Accessing the Documentation

Finding Examples

Automating the Installation of NI Products

Using NI Software with Microsoft Windows 11

Using NI Software with Microsoft Windows 10

Unsupported Windows Operating Systems


Supported Operating Systems

MXI-Express BIOS Compatibility 2023 Q1 supports the following operating systems:

Installation InstructionsWhen should I install NI MXI-Express BIOS Compatibility Software?

Use this software only if you are experiencing problems connecting your PXI or PXI Express chassis to your computer using MXI-Express. NI MXI-Express BIOS Compatibility Software works around common BIOS limitations using functionality available on MXI-Express hardware.

Install NI MXI-Express BIOS Compatibility Software if your computer does not boot when connected to your PXI chassis through MXI-Express, or if Windows does not properly discover your devices. (For example, there is a yellow exclamation point on a PCI to PCI bridge in Windows Device Manager, despite drivers for all devices being installed.) These situations often are due to programming errors in PCI Express device configuration of the BIOS. To use this software, you need a MXI-Express device that supports Mode 1 operation. Refer to Supported Hardware for more information.

Do not install NI MXI-Express BIOS Compatibility Software if your computer connects without error to your PXI or PXI Express chassis using MXI-Express. In this case, installing the software needlessly increases the system complexity and may cause errors.

Download the MXI-Express BIOS Compatibility installer from ni.com/downloads.

Note  Install this software only on a system that cannot boot with a MXI-Express connection or recognize PXI or PXI Express devices behind this connection.

Follow these steps to install the software:

You can use the above procedures to place the device back in Mode 0 (the default) for use without NI MXI-Express BIOS Compatibility Software. To do this, follow the above steps, but set DIP switch 1 back to the Off position, or for the ExpressCard-8360 or NI PCIe-8398 click the Disable button in the NI MXI Configuration program.

Note  All MXI-Express devices, including the ExpressCard-8360, retain their mode settings even after removing the board from the slot or plugging it into a different computer.

What if I have problems?

NI MXI-Express BIOS Compatibility Software detaches from a running system when booting Windows into Safe Mode. This allows a system to boot without the software affecting it, and thus allows you to uninstall the software if you run into problems.

If you have correctly configured your MXI-Express hardware for Mode 1 operation (refer to Installation Instructions) and still experience difficulties, you can either:

Troubleshooting

Issue

Troubleshooting Steps

I am seeing a code 12 or code 31 error in Device Manager on one of the devices in my chassis, or a PCI-PCI bridge or PCI Express Root Port.The Windows Event Log may contain more information about the error. The Event Log is in the Windows Control Panel under Administrative Tools. Look for events in the System log with nipximxk or nipxirfk listed as the source. Whether or not any relevant events exist in the log, contact National Instruments and report the issue.
I uninstalled the software, but now I cannot access my PXI devices. They are not present in Device Manager or MAX.Ensure that your MXI-Express device is in Mode 0. Refer to the Installation Instructions for mode setting instructions. If you are using an ExpressCard-8360, you must install NI MXI-Express BIOS Compatibility Software to access the mode setting.
I moved my MXI-Express device to another computer that does not have NI MXI-Express BIOS Compatibility Software installed. My devices in the chassis are not present in Device Manager or MAX.Ensure that your MXI-Express device is in Mode 0 for use without NI MXI-Express BIOS Compatibility Software. The configured mode is set on the device itself and follows the device when plugged into different systems. This is true for all MXI-Express devices, including those configured through software.
I cannot configure the mode of operation for my ExpressCard-8360 or NI PXIe-8398. The configuration software does not find the device.Ensure that your computer is booted into Normal Mode (not Safe Mode). MXI-Express devices are not detected in Safe Mode. If you have trouble booting into Normal Mode, be sure you have followed the instructions for changing modes in the Installation Instructions. Hot-plugging the ExpressCard-8360 solves most boot-time problems. Hot-plugging a NI PXIe-8398 is not supported.
The installer displayed a pop-up warning message about the detection of a limited bus number range.No troubleshooting steps are necessary yet. The purpose of the warning is to notify you of a BIOS setting that is limiting the amount of hardware you can attach to your computer. You may not run into this limit; however, if you do, code 12 or code 31 errors are likely to be present in Device Manager, as well as an error message in the Windows Event Log. Look for events in the System log with nipxirfk listed as the source.
I see a message in the Windows Event Log notifying me that the maximum bus number limit was reached.Not all of your PXI chassis could fit within the limitations of your motherboard, and therefore some of your devices may be missing or not working. When placing devices in your PXI system, filling the first connected chassis first ensures they are allocated resources first. Also, consolidating devices toward the left side of any non-full chassis in your system could help. If you still encounter issues with getting your devices to work, try removing some devices or a chassis. Contact National Instruments for more support on this issue.
The installer displayed a pop-up warning message about the detection of multiple PCI root buses.No troubleshooting steps are necessary yet. The purpose of the warning is to notify you of your computer's hardware configuration which divides PCI bus resources into independent segments. It is possible that the amount of hardware you can attach to your computer is limited by the size of these segments. You may not run into a limitation; however, if you do, code 12 or code 31 errors are likely to be present in Device Manager, as well as an error message in the Windows Event Log. Look for events in the System log with nipxirfk listed as the source. If you experience this problem, try inserting your MXI-Express device into a different PCI-Express slot attached to one of the other root buses.
I see a message in the Windows Event Log notifying me that the software has found a configuration that is currently not supported.Verify that the MXI-Express cable is attached to both your host PC and the PXI or PXI Express chassis, and that the PXI or PXI Express chassis is powered on at the time the host PC is powered on. It is possible to see this message if MXI-Express hardware is not detected.

Product Security and Critical Updates

Visit ni.com/security to view and subscribe to receive security notifications about NI products. For information about critical updates from NI, refer to Available Critical and Security Updates for NI Software.

New Features

Supported Hardware

Visit NI Hardware and Operating System Compatibility to view driver, desktop operating system, and real-time operating system support for individual hardware devices.

To view information for your device:

Note: Some compatibility information may only be available in the archive attached to the NI Hardware and Operating System Compatibility page. For historic driver and OS support information, refer to the readme for the relevant driver version.

Additional Hardware Support Information

NI MXI-Express BIOS Compatibility Software 2023 Q1 requires one of the following boards with the specified part numbers listed on the MXI-Express Products and MXI-Express BIOS Compatibility Software Compatibility page:

The above hardware is available in several MXI and MXI-Express kits. Contact a customer sales representative for more information.


Automating the Installation of NI Products

You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.

If the NI product you are installing uses Microsoft .NET 4.6.2, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.6.2 separately before you install NI software.

For more information about automating the installation of NI products, refer to Automating an Installer in the NI Package Manager documentation.

Using NI Software with Microsoft Windows 11

Microsoft Windows 11 is the latest version of the Windows operating system and features significant changes compared to previous versions. For more information about NI support for Windows 11, refer to NI Product Compatibility for Microsoft Windows 11.

Using NI Software with Microsoft Windows 10

For more information about NI support for Windows 10, refer to NI Product Compatibility for Microsoft Windows 10.

Unsupported Windows Operating Systems

MXI-Express BIOS Compatibility no longer supports Windows Vista/XP/7/8.x, Windows Server 2003/2008/2012, or any 32-bit Windows operating system. Versions of this product that ship after May 1, 2021, may not install or execute correctly on these operating systems. For detailed information about NI operating system support, visit https://www.ni.com/r/win32bitsupport.


上一篇:LabVIEW Modulation Toolkit 2023 Q3 Win11 32/64bitEng LabVIEW调制工具包23.5

下一篇:NI MXI-Express BIOS Compatibility 2023 Q2 x64Win10 32bitEng MXI-Express BIOS兼容性工具NIMXIeCmpt23.3

标签:MXI-Express BIOS兼容性工具23.0  PXI Express机箱与计算机之间的连接故障  PXI机箱与计算机连接故障分析  NI MXI-Express BIOS Compatibility 2023 Q1  NIMXIeCmpt2300 

在线咨询

点击这里给我发消息 售前咨询专员

点击这里给我发消息 售后服务专员

在线咨询

免费通话

24小时免费咨询

请输入您的联系电话,座机请加区号

免费通话

微信扫一扫

微信联系
返回顶部